9 TROUBLESHOOTING
Error
code
Error Display Verication item Cause Solution
E02003
Conrm the
application software
is supporting this
plotter.
When wrong delimiter
received or there is
no delimiter in the
command, this error
is shown.
Set the correct model
name.
Congure your software
application menu to
permit Graphtec plotter
control.
When the USB cable
is using, conrm too
long cable is not
used.
The wrong data is
receiving by noise on
the data cable.
Conrm it is using
good cable.
Use good cable.
When the RS-232C
interface is using,
conrm transport
setting.
The data was missing
while transport via
the interface.
Re-specify the software
application’s interface
conditions.
When the RS-
232C cable is using,
conrm the correct
wiring of cable is
using.
The wrong wiring of
RS-232C cable is
using.
Use the correct wiring of
RS-232C cable.
E02004
Conrm the
application software
is supporting this
plotter.
The numeric
parameter of an input
command exceeds its
permissible range.
Set the correct model
name.
Congure your software
application menu to
permit Graphtec plotter
control.
Conrm it is using
good cable.
When the USB cable
is using, conrm too
long cable is not
used.
The wrong data is
receiving by noise on
the data cable.
Use good cable.
When the RS-232C
interface is using,
conrm transport
setting.
The data was missing
while transport via
the interface.
Re-specify the software
application’s interface
conditions.
When the RS-
232C cable is using,
conrm the correct
wiring of cable is
using.
The wrong wiring of
RS-232C cable is
using.
Use the correct wiring of
RS-232C cable.