GREE DC INVERTER HEAT PUMP CONDENSING UNIT
17
3.2 PCB Layout
3.2.1 Interface
Indoor unit:
Model:
FLEXX24HP230V1AH
FLEXX36HP230V1AH
FLEXX48HP230V1AH
,
FLEXX60HP230V1AH
Mainboard
Printing
Interface
No.
Printing
Interface
AC-NX2
Neutral wire input
8
X9(G_SCAN)
Indoor motor check
AC-L X1
Live wire input
9
X14(OFAN-H-OUT)
AC motor high speed
output
CN3
Wired control
communication
interface
10
X11(OFAN-H-IN)
AC motor high speed input
CN1
DC motor output
11
X8(OFAN-L-IN)
AC motor low speed input
X7
Transformer Neutral wire
input
12
X6(OFAN-L-OUT)
AC motor low speed output
X13
Transformer Live wire
input
13
X3(C)
Transformer Neutral wire
output
X10(O_SCAN)
4-Way check
14
X4(R)
Transformer Live wire
output