Wired Controler XK60
42
④ The lower limit for cooling is 61°F and the upper limit for heating is 86°F.
⑤ During the “SAVE” setting, if the expected setting temperature is out of the
limit, then the limit temperature always prevail.
(2) Method 2 for setting SAVE function
:
Under OFF status, press “Timer” + “▲”buttons simultaneously for 5s
to enter into the SAVE setting status. At this time, characters or icon of
“SAVE” and cooling mode icon will be displayed; characters or icon of
“SAVE” blinks, and upper and lower temperature will be displayed at the
temperature area. Press “▲” and“▼”button to set upper and lower
temperature limit(temperature setting range is 16~30℃). Press “Mode”
button to switch cooling and heating modes. As for the cooling only
model, you can only set the lower temperature limit for the SAVE function
under cooling mode. Under SAVE setting process, press “Enter/Cancel”
or “Swing/Enter” button to save the set temperature for SAVE function
and the SAVE status, and then SAVE function will be started up.
When SAVE function is started up, press “Timer”and “▲” buttons
simultaneously again for 5s to cancel SAVE function.
SAVE setting under cooling or heating mode is shown in fig 21: