32 Memory fault Incorrect flash address
If fault appears again --> replace fan module elec-
tronics
Fault number
Description Detailed text Reset action
Mod-
ule
no.
4
33
Door switch short-circuit
Check door switch wiring, replace door switch if
necessary
4 34 Door switch interruption
4 35 Internal hardware fault ADC not working correctly
4 36 Memory fault Unable to write flash
4 37
Heating temperature sen-
sor interruption
Check sensor connection, measure sensor
4 38
Interruption of tempera-
ture sensor 2
4 39
Short-circuit heating tem-
perature sensor
4 40
Short-circuit temperature
sensor 2
0 100
Emergency stop circuit
interrupted
Emergency stop button activated
Check emergency stop button and possibly the
wiring
0 101
Fault in ultrasound gener-
ator
Internal fault in ultrasound generator
Switch device off (10 minutes) and back on, re-
place alternator if necessary