EasyManua.ls Logo

Greyline Instruments SLT32 - Intrinsic Safety Option (ISB); ISB Certification and Installation

Greyline Instruments SLT32
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SENSORINTRINSICSAFETY-OPTIONISB
SENSORMODELSPZ32T/PZ32TE/PZ12(withbuilt-intemperaturecompensation)
WhenconnectedthroughanIntrinsicSafetyBarrier,theGreylinePZ32TandPZ32TEsensorsareCSA
certifiedforinstallationinahazardouslocationrated:
ClassI,GroupsC,D
ClassII,GroupsE,FandG
ClassIII
IntrinsicSafetyBarriersmaybeorderedwiththeGreylineinstrumentandaresuppliedmountedinthe
Greylineinstrumentenclosure.Replacementbarrierfuses(PartNo.ISB-011239)maybepurchased
separately.Barriersmustbeinstalledinthesensorcablebetweenthesafeandhazardouslocations,and
mustbemountedineitherthesafeorDiv.2area.Barriersmaybeplate,busbarorrailmounted.
IntrinsicSafetyBarrierSpecifications:Certified,rated17.5Vmax,95ohmsmin.(Recommended:Stahl
Model9001/02-175-200-10).
SLT32Level&FlowMonitor
ManualSeriesB.11
Page 35
T.DUCER
N.O
C
N.C N.O
C
N.C
N.O
C
N.C
RELAY 1
RELAY 2
RELAY 3
L
N G
AC
RX
PU
GND
TX
RS 232
N.O
C
N.C N.O
C
N.C
RELAY 4
RELAY 5
N.O
C
N.C
RELAY 6
4 - 20
OPTIONAL
3
4
1
2
NOTE:
MUST BE
BARRIER-EQUIPPED UNITS
ARE FACTORY-WIRED WITH
GROUND THROUGH THE
INSTRUMENT CHASSIS.
POWERINPUT GROUND
CONNECTED TO A
GOODGROUND (<1 Ohm) WITH
A 12 AWG CONDUCTOR
REPLACEMENT FUSE ASSEMBLY
ORDERPART NO. ISB-011239 (160mA)
NON-HAZARDOUS LOCATION
HAZARDOUS LOCATION
CLASS I, GROUPS C,D
CLASS II, GROUPS E,F,G
CLASS III
INTRINSICSAFETY BARRIER
SENSOR