FLUMESELECTION
The FLUMESELECTION menuwillonlyappearin FLOW mode.
Use È and Æ toselectthecorrectFlumeorWeir.
Use È and Æ againtoselecttheSizethen È to S
tore? and Æ to Yes.
Press È or Ç tostoreflumeselectionandgetto CALIBRATION mode.
TRAPEZOIDAL:Thismenuselectionsupports60°trapezoidalflumesonly.
CUSTOMFLUMES:Experimentalorempiricaldataforanyflumeorweircanbereducedtoan
equationoftheform Q=KHn where:
Q isflowvolume
K isasscalingfactorwhichincludesflumesizeandunitsofflowmeasurement
n describestheflumenon-linearity
H isthelevelbeingmeasured
UsetheGreylineUtilityprogram FINDK&n.exe todetermine K and n constantsfromentereddata.Select
C
USTOM forflumesorweirsnotlistedintheMenu.Atthe K: promptentera‘K’constant.Atthe n:
enteran‘n’constant.
SLT32Level&FlowMonitor
ManualSeriesB.11
Page 10