discharging
power
Type of Battery lithium
/Lead-acid
lithium
/Lead-acid
lithium
/Lead-acid
lithium
/Lead-acid
lithium
/Lead-acid
lithium
/Lead-acid
Efficiency
Max. efficiency
97.2% 97.2% 97.3% 97.4% 97.5% 97.6%
Euro weighted
efficiency
97% 97% 97.1% 97.1% 97.2% 97.2%
MPPT efficiency
99.5% 99.5% 99.5% 99.5% 99.5% 99.5%
Protection devices
Safety level Class Il
Overvoltage
category
PV:II AC:III Others:I
Ingress
protection
IP65
Inverter topology
Non-isolated
Operating
temperature
range
–25°C ... +60°C (-13...+140) with derating above 45°C /113
Safety level Class I
Ingress
protection
IP65
DC switch Integrated
DC
reverse-polarity
protection
Integrated
DC Surge
protection
Type II
Insulation
resistance
monitoring
Integrated
AC surge
protection
Type II
AC short-circuit
protection
Integrated
Ground fault
monitoring
Integrated
Grid monitoring
Integrated
Anti-islanding
protection
Integrated(Active Frequency Drift)
Residual-current
monitoring unit
Integrated