GPP Series User Manual
188
Return
parameters
ISET<x>:<NR2> Sets the value of current.
VSET<x>:<NR2> Sets the value of voltage.
ISET<x>? Return the value of current.
VSET<x>? Return the value of voltage.
IOUT<x>? Returns actual output current
VOUT<x>? Returns actual output voltage.
TRACK<NR1> Sets the output of the power supply
working on independent or tracking mode.
BAUD< NR1 >Set the value of baud rate.
RCL<NR1> Recall the setting data from the
memory which previous saved.
SAV<NR1> Saves the setting data to memory.
BEEP<Boolean> Sets the BEEP state on or off.
OUT<Boolean> Sets the output state on or off.
LOCAL Return to local mode
REMOTE Return to remote mode
*IDN? Returns instrument identification.
ERR? Returns instrument error messages.
STATUS? Returns the power supply state.