REMOTE CONTROL 
189 
System Related Commands 
Read the instrument identification <string>.  
The return string contains four fields, 
each separated by a comma. The first 
field is the manufacturer, followed by 
the model name, serial number and the 
version number. 
*IDN?  
Returns the GPP identification:                                   
GW INSTEK,GPP-3323,XXXXXXXXX,V1.00 
GW INSTEK: Manufacturer, 
GPP-3323: Model name, 
XXXXXXXXX: Serial number, 
V1.00: version number. 
 
Resets the unit to RST default conditions.  
 
Save the current setup to the selected save location. 
<NRf>: 0 - 9, Corresponding to STATE00-STATE09 
*SAV 1 
Stores the setting in memory 1(STATE01).