When enabling the invert function, invert the target
waveform in instrument first, and build timer
parameter. Invert function is available for Sine,
Pulse and Ramp templets only.
:SEQUence2:TEMPlet:INVErt ON
Enable the invert function of active selected templet
for CH2.
:SEQUence[1|2]:TEMPlet:INVErt?
Queries whether the invert function under the
active selected templet is enabled.
:SEQUence2:TEMPlet:INVErt?
Returns to the templet of CH2 to check if the invert
function is ON or OFF.
:SEQUence[1|2]:TEMPlet:MAXValue{<value>|MI
Nimum|MAXimum}
Sets the maximum voltage or current value of the
active selected templet.
When voltage is the object to edit, it is the
maximum voltage to be set. When current is the
object to edit, it is the maximum current to be set.
When templet type is Pulse, the command is to set
low level value.
:SEQUence2:TEMPlet:MAXValue 5
Sets the CH2 maximum voltage of the active
selected templet as 5V
:SEQUence[1|2]:TEMPlet:MAXValue?
Queries the maximum voltage or current value of
the active selected templet.