CONFIGURATION 
103 
Internal 
Resistance 
Settings 
Sets the internal resistance of the power supply. 
0.000Ω ~ X.XXXΩ  
(Where X.XXX = Rating Voltage / 
Rating Current) 
Bleeder control turns ON/OFF the bleeder resistor. 
Bleeder resistors discharge the filter capacitors 
after power is turned off as a safety measure.  
0 = OFF, 1 = ON, 2 = AUTO 
Turns the buzzer sound on or off. The buzzer is 
associated with alarm sounds and keypad entry 
sounds. 
Sets the OCP delay time. This parameter will delay 
the amount of time it takes to trigger the over 
current protection. This function can be useful to 
prevent current overshoot from triggering OCP.  
Current Setting 
Limit (I-limit) 
Turns the current setting limit (I-limit) on or off. 
Turning this function on will prevent you from 
accidentally setting the current limit above the set 
OCP level. 
Turns the voltage setting limit (V-limit) on or off. 
Turning this function on will prevent you from 
accidentally setting the voltage limit above the 
OVP level. 
Displays which memory setting is recalled (M1, 
M2 or M3) when recalling a setup.