PSU Series User Manual 
110 
2 = Control by external resistor - 
rising   
3 = Control by external resistor- 
falling   
4 = Control by isolated board 
Output Status 
when Power-ON 
Output 
Sets the power supply to turn the output on or off 
at power up. 
0 = Safe Mode (Always OFF),  
1 = Force Mode (Always ON), 
2 = Auto Mode (Status before last 
time Power OFF) 
Master/Slave 
Configuration 
Sets the power supply as master or slave. See the 
parallel/series operation for details, page 67. 
0 = Independent  
1 = Master with 1 slave in parallel 
2 = Master with 2 slaves in 
parallel 
3 = Master with 3 slaves in 
parallel 
4 = Slave (parallel) 
Sets the external logic as active high or low for 
analog control pin 19. 
Selects the voltage monitor output range. 
Selects the external control range for external 
voltage or resistance control. 
0 = 5V [5kΩ], 1 = 10V [10kΩ] 
External Output 
Control Function 
Set external output control on or off.