PSU Series User Manual 
120 
This line uses an external voltage or resistance to 
control the output voltage. 
External voltage control (F-90: 1); External resistor 
control (F-90: 2, F-90: 3). 
0 to 5V or 0 to 5kΩ; 0 % to 100 % of the rated 
output voltage (F-97: 0). 
0 to 10V or 0 to 10kΩ; 0 % to 100 % of the rated 
output voltage (F-97: 1). 
This the common line for the external signal pins 7 
to 10, 12, 13, 19, 21, 22, 24, and 25. It is connected 
internally to the negative output. 
Output current monitor. 
0 % to 100 % of the rated output current is 
generated as a voltage between 0V and 5V (F-96: 0) 
or a voltage between 0V and 10V (F-96: 1). 
Output voltage monitor. 
0 % to 100 % of the rated output voltage is 
generated as a voltage between 0V and 5V (F-96: 0) 
or a voltage between 0V and 10V (F-96: 1). 
1.  Open collector output: 30V max, 8mA max.  
The common line for the status pins is floating (isolated voltage of 
60 V or less). It is isolated from the control circuit.