EasyManua.ls Logo

GYS E1 - Machine Interface Controls (continued); Error Codes and Troubleshooting

GYS E1
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Using the machine interface
Error codes
The following table shows a non-exhaustive list of messages and error codes that may appear.
Carry out these checks and inspections before calling in an authorised GYS technician.
If the user needs to open the product, they must turn o the power supply by disconnecting the electrical plug from the socket, and
wait two minutes for safety.
Codes
Error
Messages Solutions
001
OVER-VOLTAGE FAULT
Check the electrical installation
Have your mains supply checked by an authorised person.
002
UNDER-VOLTAGE FAULT
Check the electrical installation
005 Earth current fault
Presence of a stray current. Check the cabling of the welding acces-
sories (torch, ground clamp, electrode holder, etc.)
010
POWER SOURCE
Thermal protection
Wait a few minutes for the power source to cool down.
Ensure that the recommended duty cycle for the selected welding
current used is not exceeded.
Ensure that air inlets and outlets are not obstructed.
011
Fan
Fan default.
Switch o󰀨 the power supply by unplugging the mains connector, and
check that the fan is not blocked.
012
TRIGGER
A trigger is being pressed
Check that the trigger on the MIG/MAG torch is not blocked or stuck.
015
MOTOR
Unable to reach the required speed
Check the pressure settings on the wire-feeding rollers.
Check that the welding wire is not blocked in the torch liner.
019
Overload, please check your settings
Press and release the trigger to erase
Check the power source settings and installation (welding wire, rol-
lers, gas, torch, etc.)
If the problem persists, update the software (via Planet GYS).
020
Problem with welding start-up
Please check your welding parameters
Press and release the trigger to erase
Check the power source settings and installation (welding wire, rol-
lers, gas, torch, etc.)
If the problem persists, update the software (via Planet GYS).
024
USB overload
Disconnect your USB
Change the USB stick.
-
An internal system error has occurred.
Please restart your product
Turn the product o󰀨 and on again.
If the problem persists, update the software (via Planet GYS)
- The product’s memory space is full. Delete Jobs to free up internal storage space.
-
File %s not supported
Err %d
Continue anyway?
The data on the USB stick is corrupted. Check your data.
- Unable to write to USB stick
Free up some space on the USB key.
If the problem persists, change the USB stick..
If an error code which is not listed appears or your problems persist, contact your distributor.