file: n:\article\cos14310m5-v1_08hpc-en\20150130_cos14310m5-v1.08hpc-en_instructions_for_use_h-p-cosmos_treadmill.doc
© 2015 h/p/cosmos sports & medical gmbh author: fh email@h-p-cosmos.com created 30.01.2015 printed 30.01.2015 page: 140 of 216
9.11 Error messages
Interferences and error codes might be caused by problems with the power supply or because of insufficient
maintenance (lubrication of the running surface, etc.).
N Check voltage supply. Do not use extension cords or multi-way connectors. Connect the machine directly to the
socket in the wall. Each machine should have an individual circuit.
N Check mechanical parts for any malfunction. Check also for towels or other objects which might interfere with the
drive system.
N Check if any light barriers are dusty or incorrectly adjusted.
N Check lubrication of the running belt and lubricate if required.
N Contact problems at connectors (loose connections) caused by vibrations can result in malfunctions. Therefore
please check cables and connectors for loose connections.
The device has a self-diagnosis which recognizes some errors and displays error messages at the MCU UserTerminal
or the frequency changer/inverter (inside the device).
Error messages on devices with UserTerminal
Initiation: Running belt is not moving. One of the mode LED is flashing: (manual, profile, cardio, test)
Explanation / Display / Activity
§ $ % HELP flashing
Running machine is still functioning
N Every 1000 km (interval is adjustable) lubrication service is due. See chapter 8.4
„Lubrication of the running belt / running surface “ on page 118
N The running machine has no sensor. Lubrication according to manual only.
N Attention: Error message does not disappear automatically,
reset error message (OP 01)
= E 02 ! Service flashing
§ $ % HELP flashing
Running machine is still functioning
N Every 5000 km (interval is adjustable) general service including interior
cleansing, checking the driving belt, running belt, etc. is due.
N Every 12 months an electric safety inspection is due. See chapter maintenance
in this manual.
N Contact authorized service engineer
N Reset error message (option 01)
Elevation system
exceeded
max. value
§ $ % HELP flashing
Running machine is still functioning (except for the lift device),
N Lifting element exceeded the maximum value. The combined 0% / maximum % -
contact has been activated
N Incorrect measurement of angle of elevation
N Maybe wrongly adjusted, dirty or defective elevation sensor
N Contact authorized service engineer