Safety
9
1.3.1 Machine Behavior with the Door Open
For safety, machine operations stop when the door is open and the setup keyswitch is
locked. The unlocked position allows limited machine functions with the door open.
T1.2: Setup / Run Mode Limited Overrides with the Machine Doors Open
Machine Function Keyswitch Locked Keyswitch Unlocked
Maximum Rapid Not allowed. Not allowed.
Cycle Start Not allowed. No machine
motion or program execution.
Not allowed. No machine motion
or program execution.
Spindle
[CW] / [CCW]
Allowed, but you must press
and hold
[CW] or [CCW].
Maximum 750 RPM.
Allowed, but maximum 750 RPM.
Tool Change Not allowed. Not allowed.
Next Tool Not allowed. Not allowed.
Opening the doors while a
program runs
Not allowed. The door is
locked.
Allowed, but axis motion stops
and the spindle slows to a
maximum of 750 RPM. The doors
lock during tool changes and
some canned cycles.
Conveyor motion Allowed, but you must press
and hold
[CHIP REV] to run
in reverse.
Allowed, but you must press and
hold [CHIP REV] to run in
reverse.
CW
CCW
750 RPM Max.
750
RPM Max.
0%
0%
CHIP
FWD
CHIP
REV
CHIP
FWD
CHIP
REV
YX
Z
G00
G01