(Denotes USEPA accepted or approved for water or wastewater analysis.
Table of Contents
5940022TOC.fm Page 9
Powder Pillows
(0.01 to 0.50 mg/L NH
3
–N)
Nitrogen, Ammonia Method 10031 Salicylate Method
Test ‘N Tube
Vials HR (0.4 to 50.0 mg/L NH
3
–N)
Nitrogen, Ammonia Method 10023 Salicylate Method
Test ‘N Tube™ Vials
LR (0.02 to 2.50 mg/L NH
3
–N)
Nitrogen, Ammonium Salicylate Method
UniCell™ Vials
(1.5 to 45.0 mg/L NH
4
+
)
Nitrogen, Ammonium Salicylate Method
UniCell™ Vials
(0.05 to 1.50 mg/L NH
4
+
)
Nitrogen, Total Method 10072 Persulfate Digestion Method
Test ‘N Tube™ Vials
HR (10 to 150 mg/L N)
Nitrogen, Total Method 10071 Persulfate Digestion Method
Test ‘N Tube™ Vials
LR (0.5 to 25.0 mg/L N)
Nitrogen, Total Persulfate Digestion Method
UniCell™ Vials
(5.0 to 40.0 mg/L N (TN
b
)
Nitrogen, Total Inorganic Method 10021 Titanium Trichloride Reduction Method
Test ‘N Tube™ Vials
(0.2 to 25.0 mg/L N)
Nitrogen, Total Kjeldahl Method 8075 Nessler Method (Digestion Required)
(1 to 150 mg/L)
Organic Carbon, Total Method 10128 Direct Method
HR (100 to 700 mg/L C)
Organic Carbon, Total Method 10173 Direct Method
MR (15 to 150 mg/L C)
Organic Carbon, Total Method 10129 Direct Method
LR (0.3 to 20.0 mg/L C)
Oxygen Demand, Chemical Method 8000 Reactor Digestion Method
(3 to 150, 20 to 1500, and 200 to 15,000 mg/L COD)
Oxygen Demand, Chemical Method 10067 Manganese III Reactor Digestion Method
(with optional chloride removal)
(30 to 1000 mg/L COD Mn)
Oxygen Demand, Chemical Method 10067 Manganese III Reactor Digestion Method
(without chloride removal)
(30 to 1000 mg/L COD Mn)
Oxygen, Dissolved Method 8166 HRDO Method
AccuVac
®
Ampuls HR (0.3 to 15.0 mg/L O
2
)
Oxygen, Dissolved Method 8316 Indigo Carmine Method
AccuVac
®
Ampuls LR (6 to 800 µg/L O
2
)
Oxygen, Dissolved Method 8333 Ultra High Range Method
AccuVac
®
Ampul UHR (1.0 to 40.0 mg/L O
2
)
Oxygen Scavengers Method 8140 Iron Reduction Method for Oxygen Scavengers
Powder Pillows 5 to 600 µg/L carbohydrazide;