c. Wiring diagram of AU55NFUAHA outdoor unit
49C1
SW01 SW02
3
1
2
3
4
5
SW01
4
5
6
10
12
13
14
16
0-15
0-15
0-15
0-15
0-15
0-15
0-15
0-15
SW
03
06
07
1
2
3
1
2
3
1
1 2
1 2
1 2
1 2
ON
ON
ON
ON
LED
ON OFF
Notes:please connect the outdoor unit to the power,
then connect the indoor unit to the power,
otherwise,the failure code[95]may appear.
At this time,press the "self-check"button on the
wired controller for at least 10 senconds to delete
the failure code.(The machine's operation will
not be influenced by such a phenomenon)
*
309
*
309
1 1
33
1 1
33
1 1
22
1 1
22
1 1
33
5
4
3
2
1
5
4
3
2
1
1
1
2
2
1
1
3
3
5
5
3
1
3
1
5
5
3
1
3
1
7
7
5
5
3
3
2
2
4
6
4
1
1
2
2
4
6
4
6
1
1
2
2
4
4
1
1
3
3
5
5
2
2
4
4
1
1
3
3
1 3 5
2 4 6
A
B
1 3 5
2 4 6
A
B
1 2 3
4 5 6
3
21
43
ON
600V 20A
600V 20A
600V 20A
L1
L2
L3
N
1
1
2
2
3
4
4
3
FM1
3
1
3
1
2
2
6
6
5
5
7
7
5
5
3
1
3
1
4
4
6
6
Power 380V- 415V,3N~,50Hz
P
Q
P
Q
SV1
SV2
1 2 3
ON
SW03
1 2 3
ON
SW06
SW04 SW05
SW01 SW02 SW07
2
2
4
4
1
1
3
3
pressure sensor
high pressure(Pd)
pressure sensor
low pressure(Ps)
L1
L2
1 2
3 4
1
3
(+) (-)
(-)(-)(-)
P03
P02
P01
P04
surge
absorber
MCC-1253
F2
600V 7A
600V 7A
52C1
52C3
F1
PMV
PMV
FM1
RC01
PTCPTC
1 2
3 4
TD1
TS
CN01
CN07
CN02
CN03
CN05
CN14
TE
CN10
CN06
CN18 CN51 CN50
CN24 CN25 CN19 CN20
MCC-1332
CN08 CN17 CN28 CN27 CN09
D42 D43
+
-
+
-
1 2 3 4
1 2 3 4
+
_
+
_
W
V U
G-Tr
EZ BZ EY BY EX BX
EW BW EV BV EU BU
MCC-1252
1
1
3
3
7
7
5
5
1
1
3
3
7
7
5
5
1
1
3
3
1
1
3
3
1
1
3
3
7
7
5
5
9
9
2
2
4
4
6
6
8
8
1
1
3
3
7
7
5
5
9
9
2
2
4
4
6
6
8
8
1
1
3
3
1
3
7
52 4 6 8
1
1
3
3
5
5
1
1
3
3
2
2
4
4
1
1
3
3
1
1
3
3
2
2
3
3
5
5
1
1
1
1
3
3
2
2
4
4
1
1
3
3
1
1
3
3
5
5
7
7
1
1
3
3
2
2
1
1
ON
1 2
SW01
CN01
D25 D26 D27 D28
CN13
CN18
CN12
CN04CN05CN16CN17
CN15
CN07
CN06
CN20
CN24 CN23
P01
P02
CN22 CN25
CN21
TRS
MCC-1331
U
V
W
CM1
1
1
2
2
20SF
CH
CH
1 2
4WV
CN12
CN16
CN11
CN15
CN13
250V 20A
F3
6
8
5
7
6
8
5
7
3
1
5
5
3
1
reactor
reactor line
assembly
resistor
capacitor
resistor
capacitor
D,C,current sensor
inverter
surge absorber
A C, current sensor
shielding line earthing
noise filter
displayed information
external instruction operation state,external instruction operation: 1
operation mode of extermal option,cooling:c heating:h
intergrated operation start and stop: start:1, stop: 0
control state of fan speed prevent snowing in control: 1
control state of low noise operation at night control: 1
room units communication state information receiving: 1
room units failure code
room units capacity code
room units PMV open degree
room units TA sensor data
room units TC2 sensor data
room units TCIA sensor data
room units separate test run start:11,stop:00
displayed information
(The"0~16"under SW02 is the addresses of indoor unit)
Unit
Function
Not used
Not used
normal
Switch SW01 & LED Displayed Information(MCC-1331)
Switch
1 red (D25) 2 yellow (D26)
3 yellow (d27)
4 yellow (D28)
Overcurrent protective
circuit of GTR
compressor system
circuit
current detect
protection
high-pressure
switch system
circuit
current detect
circuit
times of protective
action
Frequency data of serial signal(receiving from MCC-1332)
Frequency data of serial signal(sending to MCC-1332)
1. Dotted line for fiels wiring.2. for terminal black the numbers inside for the terminal numbers.3. for printed circuit board.
normal
normal
normal
normal
normal
Not used
Not used
external control function switch
external control
snowing fan control
Back-up operation on Pd sensor in failure
back-up operation
Back-up operation on PS sensor in failure
back-up operation
R
W B
OR
B
R
W
BL
W
Y
R
R
BL
B
BL
BR
B
B
B
B
B
R
B
B
R
Y
B
W
W
W
OR
Y
BL
W
R
W
R
GR
BL
resister
B
BL
B
B
W
W
B
R
R
B
BL
W
R
Y
BL
BL
R
B
B
W
R
R
B
W
B
B
B
W
PU
R
W
RBLBL
W
R
W
W
R
W
BL
W
W
W
W
GR
R
R W W R
W
R
W
R
BL
B
W
BL
OR
Y
R
W
W
B
W
R
R
W
B
R
W
B
R
W
B
B
R
R
R
W
B
Y
BL
Y
BL
R
BL
BL
GR
R
GR
R
GR
R
R
W
Y
SV1,SV2
R 63H(INV)
63H1
diode
diode
rectifier
R
B
W
W
R
noise filter
noise
filter
noise filter
BL BBBBBB OR B
SW02
R
6
5
4
3
2
1
12
9
8
7
11
10
6
5
4
3
2
1
12
9
8
7
11
10
6
2
2
4
4
1
1
3
3
2
2
4
4
1
1
3
3
1
1
3
3
1
1
3
3
resister resister
2
2
4
4
1
1
3
3
3
3
1
1
1
1
3
3
1
1
3
3
CM1
52C1
52C3
PMV
63H1
RC01
SV1,SV2
20SF
CH
F1,F2,F3
49C1
TD1,TS,TE
TRS
Code
Name
Compressor (inverter)
Magnetic contactor(CM1)
Magnetic contactor(CM1)
electronic expansion valve
high-tension switch
capacitor (for FM 01)
2way-valve solenoid valve
4way-valve solenoid valve
crankcase heater for compressor
fuse(20A 600V)
inside overload protector(IOL)
temp sensor
thermostat (100*)
Y
Function explanation of dial switch(MCC-1332)
SW01 SW02
0
0
1
4
5
6
7
9
10
11
12
14
15
0
2
3
4
5
6
1
Displayed Information
failure code for outdoor unit
ng
operational mode,cooling:C,heating:H,defrost
INV target frequency
INV real frequency
number of the indoor units connceted
out door unit is in the sensor back-up operational state
confirm mis-wired (cooling operation),press sw04 for at least 2 seconds
confirm mis-wired (heating operation),press sw04 for at least 2 seconds
cooling test run,press SW04 at least 2 seconds
heating test run,press SW04 at least 2 seconds
integrated operation start and stop start:11 stop:00 normal:--
data of TD1
data of TS
data of TE
data of Pd
data of Ps
PMV open degree of outdoor unit
confirm operation of indoor remote controller:start:11 normal:
--