75
No
Yes
Yes
Yes
Yes
Yes
Yes
[98] Address setting of centralized management
Whether the
connection of wiring of the communication
line X, Y is normal
Modify the wiring connection
Whether only
the central controller
displays [98]
Whether the
secondary unit (No.2~16 unit) running in
group is connected to X, Y
communication line
Modify the connectionof communication lineof secondary unit
running in group
Whether the
address of centralized control is repeated or
exceeds 16
Modify address ofcentralized control
Check indoor PCB, ifimproper, replace it
Whether the
central controller is connected to many
units
Modify the number of unit connectedby the central controller to 1
Check central controller,if improper, replace it