65
Installation
Before starting
Operation
Screen block
diagram
Function setting Program System setting Specifications
Zone D Zone C Zone B Zone A
Low
temperature
High
temperatur
e
Setting item Function
L.SV Low set value Set lower limit.
M.SV Middle set value Set median.
H.SV High set value Set upper limit.
Lu Low limit deviation setting Set lower limit offset.
Hd High limit deviation setting Set upper limit offset.
T1~T4 Temperature 1~4 Zone setting by temperature-side group (Group 4)
H1 H Zone setting for humidity side (Group 1)
Zone separation Description
Zone A (PV≥H.SV) Always OFF regardless of offset
Zone B
(M.SV≤PV≺H.SV)
1) Hd=0(Always OFF regardless of offset)
2) Hd≠0(Refer to Fig. 107). OFF : PV≺SV+Hd ON : PV≥SV+Hd
Zone C
(L.SV≤PV≺M.SV)
1) Lu=0(Always ON regardless of offset)
2) Lu≠0(Refer to Fig. 108). OFF : PV≤SV-Lu ON : PV≻SV-Lu
Zone D (PV≺L.SV) Always OFF regardless of offset
By L.SV, M.SV, and H.SV, the range has 4 zones: A, B, C, and D.
Setting condition is L.SV < M.SV < H.SV.
Temperature
Temperature
Time
Time
Setting valu
e
Lower limit
Measurement
Setting value
Higher limit
Measurement
Output
Output
Temperature
Temperature
Time
Time
Setting valu
e
Lower limit
Measurement
Setting value
Higher limit
Measurement
Output
Output
Fig. 106) ON/OFF zone separation
Fig. 107) Zone setting 1 Fig. 107) Zone setting 2