P35i Fireplace Insert
Pellets or Corn/Pellet Mixture Only
Save These Instructions
3-90-775R15_04/13
C. Venting Requirements and
Restrictions
Acombustionblowerisusedtoextractthecombustion
gasesfromtherebox.Thiscausesanegativepressure
in the rebox and a positive pressure in the venting
system.Thelongertheventpipeandmoreelbowsused
inthesystem,thegreatertheowresistance.
The recommended maximum ue lengths for the
P35i Insert are as follows:
3" or 4" Stainless Steel Flex:30Linealft.Vertical*
4" PL Vent Pipe:
4"PlVentPipe:30Linealft.Vertical*
4"PlVentPipe:14ft.Verticalw/1-90
o
and12linealft.
horizontal*
If additional 4" PL Vent ttings are required, the
overall length must be reduced by:
Vertical90
o
orT: 2.5'
Vertical45
o
: 1.5'
Horizontal90
o
orT: 5.0'
Horizontal45
o
: 2.5'
3" PL Vent Pipe:
20Linealft.vertical*
8Linealft.verticalw/1-90
o
&8linealft.horizontal*
If additional 3" PL Vent ttings are required, the
overall length must be reduced by:
Vertical90
o
orT: 2.0'
Vertical45
o
: 1.0'
Horizontal90
o
orT: 4.0'
Horizontal45
o
: 2.0'
*Long runs of ex or PL vent pipe installed directly
vertical from the ue stub may require more frequent
cleaning due to y ash falling off inside and collecting
directly above the combustion blower outlet.
Any use of horizontal venting will require more frequent
cleaning. It is the responsibility of the installer to make
sure the entire flue configuration is accessible for
cleaning.
Stainless steel ex vent is only allowed for use in
masonry replaces and chimneys or in factory built
wood burning replace installations when used as a
linerforaclassAmetalchimney.Allpellet ventpipe
mustbesecuredtogetherbymeansprovidedbypipe
manufacturer.Thevent pipemust be securedto the
applianceuecollarwithaminimumofthreescrews.
Itisalsorecommendedthatyousealallventpipejoints
withhightemperaturesilicone.
Use only the specied venting components. Use
of any other components will void the product
warranty and may pose a hazard.
Do Not Install A Flue Damper In The Exhaust
Venting System Of This Appliance.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
NOTE: If burning a shelled corn and pellet mixture,
you must use approved venting components that
are specically designed for corn burning.

• OnlyLISTEDtypeLorPLPelletventing
componentsmaybeused.
• NOOTHERtypeofventingmaterialsor
componentsmaybeused.
• Substituteordamagedventcomponentsmay
impairsafeoperation.


• Improperinstallation,adjustment,alteration,
service,ormaintenancecancauseinjuryor
propertydamage.
• ReadandRefertoyourowner'smanual.
• Forassistanceoradditionalinformation,consulta
qualiedinstaller,serviceagencyoryourdealer.
IN CANADA: This replace insert must be installed
with a continuous chimney liner of a minimum 3"
diameter extending from the insert to the top of
the chimney. The chimney liner must conform
to the Class 3 requirements of CAN/ULC-S635,
Standard for Lining Systems for Existing Masonry
or Factory Built Chimneys and Vents, or CAN/
ULC-S640, Standard for Lining Systems for New
Masonry Chimneys.

Table of Contents

Other manuals for Harman P35I

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman P35I and is the answer not in the manual?

Harman P35I Specifications

General IconGeneral
Fuel TypePellet
Power SourceElectric
Adjustable ThermostatYes
Remote ControlYes
Overheat ProtectionYes
ColorBlack
BTU Input35, 000 BTU
Safety FeaturesAutomatic shutdown

Related product manuals