EasyManua.ls Logo

Harman P35I - Getting Started; A. Design, Installation & Location Considerations; B. Fire Safety

Harman P35I
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
P35i Fireplace Insert
Pellets or Corn/Pellet Mixture Only
Save These Instructions
3-90-775R15_04/13
3
Getting Started
A. Design, Installation & Location
Considerations
1. Appliance Location
Considerationmustbegiventosafety,convenience,trafc
ow,andthefactthattheappliancewillneedtobevented
totheoutside.This appliance may only be installed into
an existing masonry or manufactured wood-burning
replace or using the optional zero-clearance cabinet to
build into a newly constructed chase.Itisagoodideato
planyourinstallationonpaper.Useexactmeasurementsfor
clearances and oor protection, before actually beginning
theinstallation.
Maintain specied vent clearance to combustible
requirementslistedbytheventmanufacturersinstructions
andallapplianceclearancesaslistedinthismanual.
Check with your local building code agency before you
begin your installation. Local codes may supersede the
testlaboratoriesspecications.Alwaysobtainanyrequired
permit(s) so that insurance protection benets cannot be
unexpectedlycancelled.Ifanyassistanceisrequiredduring
installation,pleasecontactyourdealer.
Werecommendthataqualiedbuildinginspectorandyour
insurancecompanyrepresentativereviewyourplansbefore
andaftertheinstallation.
2. Room Sensor Location
The room sensor's location will have some effect on the
appliance'soperation.Whenthesensorislocatedcloseto
the appliance,it may requirea higher settingto keep the
rest of the house comfortable. If the sensor is located in
anadjacentroom,orfartherawayfromthestove,youwill
noticehighertemperaturesneartheappliance.
• Do NOT connect this unit to a chimney flue
servicinganotherappliance.
• DoNOTconnecttoanyforcedairdistributionduct
orsystem.
B. Fire Safety
Maintainthedesignatedclearancestocombustibles.
Insulationmustnottouchthechimney.Youmustmaintain
thedesignatedairspacearoundthechimney.Thisspace
aroundachimneyisnecessarytoallownaturalheat
removalfromthearea.Insulationinthisspacewillcause
aheatbuildup,whichmayignitewoodframing.NOTE:
Clearances may only be reduced by means approved
by the regulatory authority having jurisdiction.
To providereasonable re safety, the followingshould be
givenseriousconsideration:
1. Install at least one smoke detector on each oor of
your home. Detectors should be located away from
the heating appliance and close to sleeping areas.
Follow the smoke detector manufacturer's placement
and installation instructions, and be sure to maintain
regularly.
2. A conveniently located Class A re extinguisher to
contendwithsmallresresultingfromburningembers.
3. Apracticedevacuationplan,consistingofatleasttwo
escaperoutes.
4. Aplantodealwithahopperreasfollows:
Intheeventofahopperre:
a.Turnapplianceto"OFF".
b.Be sure hopper lid is closed and latched.
c.NotifyFireDepartment.
d.DoNOTpourwaterinthehopper.
e.Neverpulltheplugorotherwisedisconnectthe
powersupplytokillare.
FireHazard
• Donotoperateappliancebefore
reading and understanding the
operatinginstructions.
• Failure to operate properly may
causeahousere.
CAUTION
WARNING

Table of Contents

Other manuals for Harman P35I

Related product manuals