6
P35i Fireplace Insert
Pellets or Corn/Pellet Mixture Only
Save These Instructions
3-90-775R15_04/13
3
Getting Started
A. Design, Installation & Location
Considerations
1. Appliance Location
Considerationmustbegiventosafety,convenience,trafc
ow,andthefactthattheappliancewillneedtobevented
totheoutside.This appliance may only be installed into
an existing masonry or manufactured wood-burning
replace or using the optional zero-clearance cabinet to
build into a newly constructed chase.Itisagoodideato
planyourinstallationonpaper.Useexactmeasurementsfor
clearances and oor protection, before actually beginning
theinstallation.
Maintain specied vent clearance to combustible
requirementslistedbytheventmanufacturersinstructions
andallapplianceclearancesaslistedinthismanual.
Check with your local building code agency before you
begin your installation. Local codes may supersede the
testlaboratoriesspecications.Alwaysobtainanyrequired
permit(s) so that insurance protection benets cannot be
unexpectedlycancelled.Ifanyassistanceisrequiredduring
installation,pleasecontactyourdealer.
Werecommendthataqualiedbuildinginspectorandyour
insurancecompanyrepresentativereviewyourplansbefore
andaftertheinstallation.
2. Room Sensor Location
The room sensor's location will have some effect on the
appliance'soperation.Whenthesensorislocatedcloseto
the appliance,it may requirea higher settingto keep the
rest of the house comfortable. If the sensor is located in
anadjacentroom,orfartherawayfromthestove,youwill
noticehighertemperaturesneartheappliance.
• Do NOT connect this unit to a chimney flue
servicinganotherappliance.
• DoNOTconnecttoanyforcedairdistributionduct
orsystem.
B. Fire Safety
Maintainthedesignatedclearancestocombustibles.
Insulationmustnottouchthechimney.Youmustmaintain
thedesignatedairspacearoundthechimney.Thisspace
aroundachimneyisnecessarytoallownaturalheat
removalfromthearea.Insulationinthisspacewillcause
aheatbuildup,whichmayignitewoodframing.NOTE:
Clearances may only be reduced by means approved
by the regulatory authority having jurisdiction.
To providereasonable re safety, the followingshould be
givenseriousconsideration:
1. Install at least one smoke detector on each oor of
your home. Detectors should be located away from
the heating appliance and close to sleeping areas.
Follow the smoke detector manufacturer's placement
and installation instructions, and be sure to maintain
regularly.
2. A conveniently located Class A re extinguisher to
contendwithsmallresresultingfromburningembers.
3. Apracticedevacuationplan,consistingofatleasttwo
escaperoutes.
4. Aplantodealwithahopperreasfollows:
Intheeventofahopperre:
a.Turnapplianceto"OFF".
b.Be sure hopper lid is closed and latched.
c.NotifyFireDepartment.
d.DoNOTpourwaterinthehopper.
e.Neverpulltheplugorotherwisedisconnectthe
powersupplytokillare.
FireHazard
• Donotoperateappliancebefore
reading and understanding the
operatinginstructions.
• Failure to operate properly may
causeahousere.
CAUTION
WARNING