Pellets or Corn/Pellet Mixture Only
P35i Fireplace Insert
Save These Instructions 3-90-775R15_04/13
6
Mobile Home
A. Mobile Home Installation
Outside Air Kit #1-00-774280 Must be used
for installation in a mobile home.
1. An outside air inlet must be provided for
combustionair,andmustremainclearofleaves,
debris,ice,and/orsnow.Theoutsideairpathmust
beunrestrictedwhiletheapplianceisinoperation.
2. The combustion air intake system must be of
metalconstruction.Itmustpermitzero-clearance
to combustible materials, and contain a rodent
screen.
3. The appliance must be secured to the mobile
home structure by boltingitto the oor. Use the
correct length lag-bolts through the same holes
thatsecuredtheappliancetotheshippingpallet.
4. The appliance must be grounded to the metal
framingofthemobilehome.
5. Allclearancestocombustiblesandoorprotection
requirementsmustbefollowed.
6. Follow the vent manufacturer's instructions
when installing in a mobile home. Use silicone
or equivalent tocreatean effective vaporbarrier
wherethechimneyorothercomponentpenetrates
totheexteriorofthemobilehome.
7. Installation shall be in accordance with the
ManufacturedHome andSafetyStandard (HUD)
CFR3280,Part24
8. Theappliancemustneverbeinstalled inaroom
designatedforsleeping.
9. Thespaceheatermustbeconnectedtoafactory
built chimney conforming to CAN/ULC-S629.
Maximum 8 inch diameter. Chimney must be
removabletoallowtransportofmobilehome.
InstallationmustcomplywithManufacturedHomeand
SafetyStandard(HUD),CFR3280,Part24.
CAUTION
Maintain structural integrity of mobile home:
Floor, wall, ceiling and/or roof.
DoNOTcutthrough:
• Floorjoist,wallstuds,orceilingtrusses.
• Anysupportingmaterialthatwouldaffectthe
structuralintegrity.
CAUTION
Neverdrawoutsidecombustionairfrom:
• Wall,oororceilingcavity.
• Enclosedspacesuchasanatticorgarage
There are a few holes in the bottom of the insert
mountingframewhichcanbeusedforlagbolts.Use
atleasttwooftheseholesforsecuringtheappliance
tothereplaceoorinamobilehomeinstallation.The
installerwillneedtodetermineandobtaintheproperly
sizedlagboltsandmasonryanchors.
Four 5/16 -18 Leveling
bolts may be installed
in each corner
Numerous holes allow
for lag bolts (2 min.)in
mobile home installation
Never install in a room intended for sleeping.