EasyManua.ls Logo

Harman P35I - F. Starting a Fire - AUTOMATIC; G. Maintaining the Fire; H. Shut-Down

Harman P35I
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
Pellets or Corn/Pellet Mixture Only
P35i Fireplace Insert
Save These Instructions 3-90-775R15_04/13
J. Shut-Down
DuringoperationinROOMTEMP/AUTOMATICmode,
theappliancewillshutdownnaturallywhendemandis
metorexceeded.Inothermodesofoperation,theunit
willshut-downonlyiforwhenitrunsoutoffuel.
To kill or stop a re, turn the mode selector dial to
"OFF". The shut down cycle will slow or stop the
feedertograduallycoolthereandensurethatallof
theexhaustgasesaresafelyexpelledbeforestopping
thecombustionblower.Thisnotonlyensuresremoval
of all smoke and gases, it also keeps the re from
attemptingtotravelintothefuelstoragehopper.Forthis
reason; Hearth & Home Technologies recommends
installing a battery back-up in areas where frequent
poweroutagesareexperienced.(Alsoseepage13)
NEVER ATTEMPT TO KILL A FIRE BY PULLING
THE PLUG OR OTHERWISE DISCONNECTING
THE ELECTRICITY SUPPLY.
The best way to kill a re, especially at the end of the
heating season, is to simply allow it to run out of fuel.
I. Relaxation Mode
Anaddedfeatureforthosetimes whenyou'dlike to
unwindwatchingarebutyetdonotwantalltheheat.
Withtheigniterswitchinthe"MANUAL"positionand
themodeselectorin"STOVETEMP",yourtemperature
dialcanbesetuptoa#3andthedistributionblower
willbedisabled.Asyouturnupthetemperaturedial
and the re begins to burn hotter, the distribution
blowerwillbegintooperate.
G. Starting a Fire - "AUTOMATIC"
1. Withthemodeselectorinthe"OFF"position,and
theFeedAdjusterNOTon"Test",plugthepower
cordintoaproperlygroundedreceptacle.
2. FillthehopperwithDRYfuel.
3. TurntheFEEDADJUSTERdialto"Test".Thiswill
runthefeedmotorforoneminute.Ifyoubeginto
see fuel entering the burn pot, you can stop the
testcycle.Returnto#4or#5tostartout.
4. PositiontheIgniterswitchtoAUTOMATIC.
5. Turnthemodeselectordialtothedesiredmode.
Thiswillstartthecombustionblower,feeder,and
igniteroperating.If Room Temp is selected, be
sure to turn the temperature dial above the
current room temperature.
6. After the initialfeed cycle istypically when you'll
begintoseesparks,smoke,orames.
Keep Hopper Lid, Ash Pan, and Fire viewing doors
closed while in operation. Maintain all door seals
and gaskets in good condition. Replace gaskets
when necessary using parts obtained through
your Harman® dealer.
H. Maintaining the Fire
Once the Distribution Blower begins operation, your
reiswellestablished.Now,youcanmakeanydesired
adjustments to the temperature dial. Remember, in
STOVE TEMP, the temperature dial uses the inner
portionofthescale(#1thru7).InROOMTEMP,select
thedesiredtemperatureinFahrenheitfrom 50to90
degrees.
Theamesshouldappearbriskandbright.Ifyousee
deeporangeandlazyames,itisusuallyanindication
that the burn pot needs to be cleaned. Refer to the
MaintenanceSectionofthismanual.
    Keep combustible
materials, gasoline, and other ammable vapors or
liquidsclearofthisappliance.
• DoNOTstoreammable materialsinthevicinity
ofthisappliance.
• DO NOT BURN GARBAGE OR FLAMMABLE
FLUIDS SUCH AS GASOLINE, NAPTHA OR
ENGINEOIL.
• DO NOT USE CHEMICALS OR FLUIDS TO
STARTAFIRE.
Keep all such liquids well away from the heater while it
is in use, combustible materials may ignite!

Table of Contents

Other manuals for Harman P35I

Related product manuals