Input Level
Meter
Shows the input level
at the selected point in
the input channel signal
path.
The overload (OVL) LED indicates an overloaded
analogue input (mic preamp clipping). 0 on the meter
indicates -18dBFS (+4dBu out).
-36dB
(-32dBu out)
+18dB
(+22dBu out)
Input Gain
Reduction
Meter
Shows the overall gain
reduction of the limiter
and compressor stages,
if they are engaged.
No gain
reduction
20dB gain
reduction
Vi1000 USER MANUAL
12.1 12.1: METERING > INPUTS
12.1: METERING > INPUTS
Each input channel has an input meter and every input meter has two parts: A 20--segment level meter (top), and a
9-segment Gain Reduction Meter (GRM).
Both the measured point in the channel signal ow and the metering peak hold time can be selected in the main
settings screen (via the [MENU] button), in the (Settings) tab.
Input Channel Metering