Bus Meters
Show the buss master
signal levels.
Bus Masters can be congured as stereo channels,
therefore the Bus Master Strip level meters have left
and right meters (i.e. the left and right channels share
a single set of controls, but note that this feature is
reserved for a future release). The GRM shows the
overall gain reduction of the limiter and compressor,
if they are engaged. The Dynamics from Stereo Bus
Masters are always linked, therefore both GRMs show
the same value.
The overload LED indicates a value that is higher than
Full Scale (analogue output-stage clipping).
-36dB
(-32dBu out)
+18dB
(+22dBu out)
Mix Master
Meters
The L,R and C Output
Masters each have a
Level Meter and a Gain
Reduction Meter. The
L and R masters share
a stereo meter, and the
C master has a mono
version.
The overload LED indicates a value that is higher than
Full Scale (analogue output-stage clipping).
-36dB
(-32dBu out)
+18dB
(+22dBu out)
Monitor Bus
Metering
The monitor section has
a stereo level meter,
but there is no GRM
associated with the
monitor.
-36dB
(-32dBu out)
-36dB
(-32dBu out)
Vi1000 USER MANUAL
12.2 12.2: METERING > BUSSES
12.2: METERING > BUSSES