5
4.3 Power Supply
Electrical connections must be made by a qualified electrician in compliance with all
relevant codes. This machine must be properly grounded to help prevent electrical
shock and possible fatal injury.
The band saw is factory wired for 230 volt
and its operating amp rating is 10 A. It i
recommended that the band saw b
connected to a grounded and dedicated 2
amp circuit with a 20 amp circuit breaker o
time delay fuse. Local codes tak
precedence over recommendations.
4.4 Grounding
This tool is equipped with an electric cor
having an equipment-grounding conducto
and a grounding plug. The plug must b
plugged into a matching outlet that i
properly installed and grounded in
accordance with all local codes and
ordinances .Do not modify the plug provided.
If the plug will not fit the outlet have th
proper outlet installed by a qualified
electrician.
4.5 Extension Cords
Use Table 1 as a general guide in choosing the correct size cord. The smaller the gauge
number, the heavier the cord. If in doubt, use the next heavier gauge.
Recommended Gauges (AWG) of Extension Cords
Table 1
Ampere rating
Volts Total length of cord in feet
120 25 50 100 150
240 50 100 200 300
More than Not more than Minimum gauge cord
0 6 18 16 16 14
610 18161412
10 12 16 16 14 12
12 16 14 12 NR NR
NR: Not Recommended.
4.6 Dust Collection
The use of a dust collection system is strongly recommended for this band saw. It will help
keep the shop clean, as well as reduce potential health hazards caused by inhalation of
wood dust. The collector should have a capacity sufficient for this size machine – 400 CFM
is recommended.