Remote Software
Gladiator Gen 3 Microwave Series
21
Diagnostic Description Notes
Sensor
Value
Sensor value indicates the amount of signal blocked from
0-100%. 0% is full signal, 100% is complete blockage.
SW On
For the level relay to switch to state '2', the Sensor value
must exceed this SW On % for the duration of the on delay
time.
SW Off
For the level relay to switch to state '1', the Sensor value
must drop below this SW Off % for the duration of the off
delay time.
Switch mode 'Auto' will
automatically set the SW Off
% to 2/3rds of SW On %
Max The maximum recorded Sensor value % since last log reset
Min The minimum recorded Sensor value % since last log reset
Delay Dynamic switch delay time indication
Temp Measured temperature inside Receiver unit
• Normal
• Recover
• Failed
• Unit in normal operation
• Unit applying 'Recover' Gain to retain or enhance signal
• Unit is in failsafe condition
Unit will indicate Recover
commonly for blocked
chute and other switching
applications.
Signal
Signal strength measured at the Receiver.
This value is proportionate to the Sensor Value %:
• 0V = Sensor Value 100%. No Signal
• 1V = Sensor Value 50%. Half Signal
• 2.0V = Sensor Value 0%. Full Signal
• 2.0V to 2.5V = Sensor Value 0%. Full signal
In most modes the unit will be
looking to hold a 2.5V signal.
2.0V to 2.5V is used for signal
stability purposes.
Recover
Recover Gain % applied. Recover Gain is used retain the
incoming signal during difficult conditions.
The programmed App Type
will have pre-defined amounts
of Recover Gain available.
Gain
Gain % applied. This is the total Gain
(Calibrated Gain plus Recover Gain) applied by the system.
Noise
Noise interference in V - Noise from interfering received
frequencies or along the communications wiring.
It is normal to see a small
consistent amount of Noise.
• Remote
• Master
• Slave
• Remote: (default). Standard remote system
• Master: Unit mode is set as 'Master' for cross-talk prevention
• Slave: Unit mode is set as 'Slave' for cross-talk prevention