Cross-Talk Prevention
28
Gladiator Gen 3 Microwave Switch Series
Cross-Talk Prevention - Remote
• Up to four remote Microwave systems can be set up for anti-crosstalk.
• For two systems, one can be set to operating mode ‘Master’ and the other to operating mode ‘Slave’.
• For up to four systems, a dedicated Sequencing control unit must be used with the four systems set to
operating mode ‘Slave’.
• See user manual for further information.
+
–
A
1L
+
–
N
B
RED
BLACK
BLUE
WHITE
BROWN
Is
SENSOR DC-In AC-In*4-20mA (N/A)
COMMS
MIC-SENDER
RED
BLACK
BROWN
SLAVE IN
MASTER OUT
TEST IN
RELAY 1
NC
COM
NO
RELAY 2
NC
COM
NO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
GLADIATOR MICROWAVE REMOTE AMPLIFIER -
SLAVE
Ground
+
–
A
1L
+
–
N
B
RED
BLACK
BLUE
WHITE
BROWN
Is
SENSOR DC-In AC-In*4-20mA (N/A)
COMMS
MIC-SENDER
RED
BLACK
BROWN
SLAVE IN
MASTER OUT
TEST IN
RELAY 1
NC
COM
NO
RELAY 2
NC
COM
NO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
GLADIATOR MICROWAVE REMOTE AMPLIFIER -
MASTER
GMSEQ MICROWAVE SEQUENCER
com
com
com
com
Tx
CH1 CH2 CH3 CH4
Tx
Tx
Tx
TO
SLAVE 3
TO
SLAVE 4
+
–
A
1L
+
–
N
B
RED
BLACK
BLUE
WHITE
BROWN
Is
SENSOR DC-In AC-In*4-20mA (N/A)
COMMS
MIC-SENDER
RED
BLACK
BROWN
SLAVE IN
MASTER OUT
TEST IN
RELAY 1
NC
COM
NO
RELAY 2
NC
COM
NO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
GLADIATOR MICROWAVE REMOTE AMPLIFIER -
SLAVE
+
–
A
1L
+
–
N
B
RED
BLACK
BLUE
WHITE
BROWN
Is
SENSOR DC-In AC-In*4-20mA (N/A)
COMMS
MIC-SENDER
RED
BLACK
BROWN
SLAVE IN
MASTER OUT
TEST IN
RELAY 1
NC
COM
NO
RELAY 2
NC
COM
NO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
GLADIATOR MICROWAVE REMOTE AMPLIFIER -
SLAVE
+
–
A
1L
+
–
N
B
RED
BLACK
BLUE
WHITE
BROWN
Is
SENSOR DC-In AC-In*4-20mA (N/A)
COMMS
MIC-SENDER
RED
BLACK
BROWN
SLAVE IN
MASTER OUT
TEST IN
RELAY 1
NC
COM
NO
RELAY 2
NC
COM
NO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
GLADIATOR MICROWAVE REMOTE AMPLIFIER -
SLAVE
Ground
+
–
A
1L
+
–
N
B
RED
BLACK
BLUE
WHITE
BROWN
Is
SENSOR DC-In AC-In*4-20mA (N/A)
COMMS
MIC-SENDER
RED
BLACK
BROWN
SLAVE IN
MASTER OUT
TEST IN
RELAY 1
NC
COM
NO
RELAY 2
NC
COM
NO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
GLADIATOR MICROWAVE REMOTE AMPLIFIER -
MASTER
GMSEQ MICROWAVE SEQUENCER
com
com
com
com
Tx
CH1 CH2 CH3 CH4
Tx
Tx
Tx
TO
SLAVE 3
TO
SLAVE 4
+
–
A
1L
+
–
N
B
RED
BLACK
BLUE
WHITE
BROWN
Is
SENSOR DC-In AC-In*4-20mA (N/A)
COMMS
MIC-SENDER
RED
BLACK
BROWN
SLAVE IN
MASTER OUT
TEST IN
RELAY 1
NC
COM
NO
RELAY 2
NC
COM
NO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
GLADIATOR MICROWAVE REMOTE AMPLIFIER -
SLAVE
+
–
A
1L
+
–
N
B
RED
BLACK
BLUE
WHITE
BROWN
Is
SENSOR DC-In AC-In*4-20mA (N/A)
COMMS
MIC-SENDER
RED
BLACK
BROWN
SLAVE IN
MASTER OUT
TEST IN
RELAY 1
NC
COM
NO
RELAY 2
NC
COM
NO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
GLADIATOR MICROWAVE REMOTE AMPLIFIER -
SLAVE
Master / Slave Wiring
Sequencer / Slave Wiring