Remote Software
Gladiator Gen 3 Microwave Series
23
Parameter Description Options
App Type
(see next page for
additional information
about Application Types)
Select application pre-set. This automatically
configures the unit to the recommended settings
for each specific application.
Note: you must perform a Cal Mount after
changing or selecting App Type
• 4-20mA (Density)
• Switch
• Boom Protect
• Blocked Chute
• Alignment
Cal Mounting
Performs a Cal Mount in which the unit
automatically configures itself based on the
selected App Type and the mounting environment.
• Yes / No
Switch Point
This is the switch on / off sensor value % for relay
actions
• Auto - 75% (on) 50% (off)
• Manual (set in Advanced)
On Delay Adj
Set on delay time for the first relay. If using the
2nd relay in cleaner / maintenance mode 1/2 of
this value will be the duration of the relay timer
• Adjustable in seconds
Relay1Action
Adjust the Relay action to be energised or
de-energised during normal operation
• FailSafe Hi
• FailSafe Low
Lock Code Set a lock code to prevent unauthorised access • Default 0
Quickset Menu - Parameters