34
Part Numbering
Gladiator Gen 3 Microwave Series
Remote Version
RemoteAmplier
GSA Gladiator Amplifier (compatible with all Gladiator products), Modbus
Housing
S Polycarbonate
Power Supply
B 12-30 VDC
C 36-60VDC
U 12-30VDC and 90-260VAC
Output Options
S 2 Relays (relay 1 primary switch, relay 2 secondary switch OR Failsafe / Cleaner /
Maintenance alarm)
X Option ‘S’ plus 4-20mA output
Approval
A22 ATEX Grp II Cat 3 GD T85°C IP67 Tamb -4C to 70°C
GSA S U S
Remote Sender / Receiver
GMSB Gladiator Microwave Sender
GMRR Gladiator Microwave Remote Receiver
Frequency
1 10.525 GHz
Transducer Facing Material Selection
0 UHMW Polyethylene
1 PTFE Teflon
Transducer Housing Material
1 Aluminium / Mild Steel
2 316L Stainless Steel
Output Option
X Not Required - Outputs generated from GSA amplifier
Approval Standard
X Not Required
A22 ATEX Grp II Cat 3 GD T85°C IP67 Tamb -4C to 70°C
2D
F
acing Material: 0 (UHMW) IECEx ta tb IIIC T* Da Db Tamb = -30°C to +55°C
Facing Material: 1 (PTFE) IECEx ta tb IIIC T* Da Db Tamb = -30°C to +8C
GMSB 1 0 1 X X
CA-GMR Pre-cut cable for remote
sender or receiver
10 10m cable
20 20m cable
30 30m cable
50 50m cable
100 100m cable
CA-GMR 10
Connection Cable
Lengths above
100m available via
special order
*Consult Safety Instructions