Cross-Talk Prevention
Gladiator Gen 3 Microwave Series
29
Cross-Talk Prevention - Integral Systems
The GMSEQ Microwave sequencer will operate as the pulse control (Master) for up to 4 Integral systems.
Each connected Microwave system will operate as a Slave. The Sequencer will pulse control from CH1 to CH2
to CH3 to CH4 then return to CH1.
More than one system can be connected to each channel, note that each system connected to the same
channel will be part of the same slave ‘sequence’ in the pulsing.
First, the Sequencer On and Off time (in Quickset menu of Sequencer) must be set to the following values.
•Ontime–2000μs
•Offtime–2000μs
Wiring
Please note units still require external power source.
com
com
com
com
Tx
CH1 CH2 CH3 CH4
Tx
Tx
Tx
1 2 3 4 5 6 7 8
9 10
Slave System 1
1 2 3 4 5 6 7 8
9 10
To 3rd
System
To 4th
System
A
1L
+
N
B
DC-In AC-In
COMMS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
G1S or GMS
Sender
G1Q or GMSRQ
Receiver
1 2 3 4 5 6 7 8
9 10
Slave System 2
1 2 3 4 5 6 7 8
9 10
G1S or GMS
Sender
G1Q or GMSRQ
Receiver
GMSEQ Sequencer
System Calibration
To set up the Microwave systems, perform as per below.
1. Complete wiring of all units to be used in the Sequenced network and apply power.
2. Run setup / calibration as per normal installation instructions.