EasyManua.ls Logo

Hawk Gladiator - Specifications

Default Icon
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
Specications
Gladiator Gen 3 Microwave Series
Operating Voltage
• Integral 12-30VDC / Remote 12-30VDC
(residual ripple no greater than 100mV)
• Integral 80-260VAC / Remote 90-260VAC 50 / 60Hz.
• Remote 36-60VDC
Power Consumption
• <0.8W @ 24VDC • <3VA @ 115VAC
• <6W @ 48VDC • <5VA @ 240VAC
Communications
• GosHawk, Modbus • 4-20mA
• Multidrop mode can address 1-250 units over 4 wires.
Relay Output: (1) SMART (2) Remote
• Form ‘C’ (SPDT) contacts, rated 5A at 240VAC resistive
• Remote fail-safe test facility for one relay.
Operating Temperature
• Remote electronics -40°C (-40°F) to 80°C (176°F)
• Integral Units -30°C (-20°F) to 65°C (150°F)*
• Remote Sensors -30°C (-20°F) to 65°C (150°F)*.
*For higher temperature applications, remote mounting
with refractory windows is necessary.
Power Density
• Rated from emitter to receiver at approximately 20µW/cm²
• Complies with FCC Title Rules Part 15 (Beam Blockage)
• Caution sign posting not required.
Transmitted Signal
• Circular transmission polarity
• Frequency: 10.525GHz • Sensitivity -95dBm
• Power: +20dBm/100mW • Beam width 25º
Fail-Safe
• Selectable - presence or absence of material
• High level fail-safe:
relay is activated when material is present
• Low level fail-safe:
relay is activated when no material is present.
Range
• Maximum range under ideal conditions: 1200m (656ft)
• Minimum range under ideal conditions: 10cm (4 inches).
Note: Minimum ranges are dependent on application
conductivity.
Sender/ReceivertoAmplierSeparation
• Up to 500m (1640ft) using specified extension cable.
AlternatecabletypebetweenAmplierandSensors
• 6 or 8 conductor (5 used) shielded twisted pair
instrument cable
• Conductor size dependent on cable length
• BELDEN 3120A, DEKORON or equivalent
• Max: BELDEN 3120A = 500m (1640 ft). 3 pairs,
1 conductor not used
• Max: DEKORON IED183AA004 = 350m (1150 ft).
4 pairs, 3 conductors not used.
Maximum Operating Pressure
• 2 BAR
Display (Remote version only)
• 2 line x 12 character alphanumeric LCD
• Backlight standard.
Memory - Remote
• Non-Volatile (No backup battery required)
• >10 years data retention.
Enclosure Sealing
• Integral Sensors IP66/67 • Remote Sensors IP66/67
• Remote Electronics IP65 (NEMA 4x).
Cable Entries
• Remote Sensors:
1xM20 Gland / 3/4” NPTF threaded adaptor
• Remote Amplifier:
4x20mm (0.8”), 1x16mm (0.6”) knock outs
• Integral Units:
2xM20 Glands / 3/4” NPTF threaded adaptors.
Mounting
• 3” male NPT thread or four 10mm (0.4”) holes in flange
• MA12 / MA13 adjustable mounting bracket
Environment Seal
• 3, 4” and 6” weldments for standard mounting on
vessel wall with PTFE and UHMW windows
• Flange for mounting separate from vessel wall -
isolation shock mounts are available
• Ceramic window assemblies
• Firebrick window assemblies available on custom basis
• Waveguides - custom assemblies available for high
temperature and limited access applications.
Weight
• GSA 1kg • GMS 5kg • GMR 5kg
Approval
• IECEx Zone 20/21, Zone 21
• Ex ta tb IIIC T* Da Db Tamb -30°C to +80°C / Tamb = -30°C
to +55°C (model dependent)
• IP66
*Consult Safety Instructions

Table of Contents

Other manuals for Hawk Gladiator

Related product manuals