4 – 28 HEIDENHAIN Technical Manual TNC 426, TNC 430
MP2421.0-1 Proportional factor of the spindle current controller for wye
and delta connection
Input: 0.00 to 9999.99 [VA]
6 – 213
MP2431.0-1 Integral factor of the spindle current controller for wye and
delta connection
Input: 0.00 to 9999.99 [V/As]
6 – 213
MP2500.0-8 Proportional factor of the speed controller for axes 1 to 9
Input: 0 to 1 000 000.000 [As]
PLC 6 – 135
MP2501.0-1 Proportional factor of the spindle speed controller for wye
and delta connection
Input: 0 to 100 000 000.000 [As]
PLC 6 – 212
MP2510.0-8 Integral factor of the speed controller for axes 1 to 9
Input: 0 to 100 000 000 [A]
PLC 6 – 135
MP2511.0-1 Integral-action factor of the spindle speed controller for wye
and delta connection
Input: 0 to 100 000 000 [A]
PLC 6 – 212
MP2512.0-8 Limiting the integral-action component of the speed
controller for axes 1 to 9
Input: 0.000 to 30.000 [s] (realistically: 0.1 to 2.0)
PLC 6 – 49,
6 – 139
MP2520.0-8 Differential factor of the speed controller for axes 1 to 8
Input: 0 to 1.0000 [As]
PLC 6 – 136
MP2521.0-1 Differential factor of the spindle speed controller for wye
and delta connection
Input: 0 to 1.0000 [As]
PLC 6 – 212
MP2530.0-8 PT
2
element of the speed controller (2nd-order delay) for
axes 1 to 8
Input: 0 to 1.0000 [s]
PLC 6 – 137
MP2531.0-1 PT
2
second-order time delay element of the speed
controller for the first spindle for wye and delta connection
Input: 0 to 1.0000 [s] 0 = 0.001 s
PLC 6 – 212
MP2540.0-8 Band-rejection filter damping for axes 1 to 8
Input: 0.0 to 18.0 [dB]
PLC 6 – 137
MP2541 Band-rejection filter damping of the spindle
Input: 0.0 to 18.0 [dB]
PLC 6 – 212
MP Function and input Software
version and
behavior
Page