Protocol description ASCII, SECS/HSMS
Customer manual
Version 1.2
LFM LP Reader 15.01.2019
Page 102 of 119
HERMOS AG
Gartenstrasse 19 Tel. +49(9279) 991-0
D-95490 Mistelgau Fax. +49(9279) 991-100
22
0x16
Page number for readmode
00
The page to read for readmode 00:
0: Read all transponders
1: Page 1 Read multipage transponders
...
17: Page 17 Read multipage transponders
240: read read-only transponder
241: read read-write transponder
Default 0 (read all transponders)
23
0x17
Triggered read frequency
For a read / write error, the triggered reading
frequency sets the time between two read /
write attempts for a transponder;
Read frequency in case of a triggered read (no
polling)..
02 10 (1/10s)
Default : 5 (0,5s)
24
0x18
r/w max repeat
Maximum number of read and write retries
0 … 255
Default : 5
25
0x19
Transponder Type
The parameter defines the validity of the read data
of the transponder.
00 … read / write type TIRIS
Each transponder page consists of 8 data bytes
and 2 bytes CRC checksum. The validity of the
data bytes is verified by a checksum
01 … A transponder page is interpreted as 10
data bytes without checksum .
Default: 0
26
0x1A
Sensor Activity
Activate / Deactivate.
0 ... Sensor not activated
1 ... sensor activated
Default : 1