Protocol description ASCII, SECS/HSMS
Customer manual
Version 1.2
LFM LP Reader 15.01.2019
Page 107 of 119
HERMOS AG
Gartenstrasse 19 Tel. +49(9279) 991-0
D-95490 Mistelgau Fax. +49(9279) 991-100
antenna powerage of the
last read/write action
(read only)
The read-only parameter returns the antenna
power from the last read or write action. Only
available if there was a read or write action
before.
Software Version String
(read only)
The read-only parameter returns the complete
identifier of the current firmware.
Serial number string
(read only)
The read-only parameter provides the complete
serial number string.
Hardwarerevision String
(read only)
The read-only parameter provides the complete
identifier for the hardware version.
Antenna tuning of the
antenna 1
By automatically adjusting the antenna, the
influence of interference can be minimized.
00 ... 15 Value of the automatic adjustment
Time how long the test and tune LED’s indicate
the last read, write or tune result.
0 without timeout
1 ... 255 (100 ms)
Default : 50 (5s)
Provides the ability to show tuning errors
detected during operation permanently without
timeout (Par. 84)
0 show with timeout
1 ignore timeout and show always
Default : 0
All (the most) parameters of the reader will be
set to default values. The set protocol is
retained. There is no protocol change!
0… reset all parameters to their default value
1… reset all parameters to their default value,
but the network settings are retained
This parameter provides information about the
currently set protocol. The automatic protocol
selection distinguishes between the "ASCII"
and the "SECS" protocol. Setting the
parameter leads to a restart of the reader when
the protocol is changed.
1 … SECS/HSMS
2 … ASCII
Default : 2