Protocol description ASCII, SECS/HSMS
Customer manual
Version 1.2
LFM LP Reader 15.01.2019
Page 63 of 119
HERMOS AG
Gartenstrasse 19 Tel. +49(9279) 991-0
D-95490 Mistelgau Fax. +49(9279) 991-100
O – Permanently switch on LED1 external LED:
>> O111100 or O1111
<< 011
Command O
Reader-ID 1
Head-ID 1
Output Nr 1
Output State 1
Timeout 00 optional (00=permanently)
O – Turn LED3 blue test LED on for 10 seconds:
>> O11310A
<< 011
Command O
Reader-ID 1
Head-ID 1
Output Nr 3
Output State 1
Timeout 0A
O – Get the state of all outputs
>> Q01
<< q012000000001
external LED (2 = flash), green status LED (1 = on)
Command q
Reader-ID 0
Head-ID 1
Output State LED1 2 FLASH
Output State LED2 0 OFF
Output State LED3 0 OFF
Output State LED4 0 OFF
Output State LED5 0 OFF
Output State LED6 0 OFF
Output State LED7 0 OFF
Output State LED8 0 OFF
Output State LED9 0 OFF
Output State LEDA 1 ON
O – Get the sensor state
>> Q00
<< q000
sensor state 0 released
Command q
Reader-ID 0
Head-ID 0
Sensor State 0 Released