Protocol description ASCII, SECS/HSMS
Customer manual
Version 1.2
LFM LP Reader 15.01.2019
Page 82 of 119
HERMOS AG
Gartenstrasse 19 Tel. +49(9279) 991-0
D-95490 Mistelgau Fax. +49(9279) 991-100
Where used S3F5, S3F7, S3F13
PM Information Format: A[2]
Information about the operating mode
"NE" … normal execution
"MR" … operating mode "maintenance" required
Where used S18F2, S18F4, S18F8, S18F10, S18F12, S18F14
RAC Format: B[1]
Confirmation code reset
0 … Reset could be executed
1 … Reset could not be executed
Where used S18F20
RIC Format: B[1]
1 … Power-up-Reset
2 … Software reset (without reset of the Ethernet component)
Where used S2F19
SHEAD Format: B[10]
Head of the stored SECS message block. Only the last message is saved. This must be confirmed by
the host.
Where used S9F9
SOFTREV Format: A[max 6]
Software version
Where used S1F2
SSACK Format: A[2]
Description: Result information about the status of the request for the service request.
"NO" Normal Operation
Indicates the success of the requested operation.
"EE" Execution error