RS Dehumidifiers for radiant systems
32 - 52
RSO and RSV MODELS
RSE and RSVE MODELS
HYGROSTAT CONNECTION: CONNECT TO THESE 2 CLAMPS THE DRY CONTACT OF THE HYGROSTAT.
IF THE HYGROSTAT NEED TO BE SUPPLIED 230 V, CONNECT IT IN PARALLEL TO THE DEHUMIDIFIER ELECTRICAL
SUPPLY (F and N CLAMPS)
FAN CONNECTION: MEDIUM SPEED WIRE 6; HIGH SPEED WIRE 7.
FACTORY SETTING: MEDIUM VELOCITY
IF MEDIUM VELOCITY IS NOT SUFFICIENT MOVE WIRE 61 AND CONNECT TO WIRE 7.
ELECTRICAL SUPPLY CONNECTION: CONNECT PHASE, NEUTRAL AND PE
PROTECT THE DEHUMIDIFIER AND THE LINE WITH A PROTECTION UPSTREAM
(REFERS TO THE PARAGRAPH “ELECTRICAL CONNECTIONS” FOR THE SUGGESTED PROTECTION)
BUS RS485 CONNECTION [OPTIONAL]: CONNECT TO THESE 2 CLAMPS THE BUS LINE COMING FROM THE DOMOTIC
OR SUPERVISION SYSTEM.
REFERS TO THE SERIAL MANUAL RS485
ELECTRICAL SUPPLY CONNECTION: CONNECT PHASE, NEUTRAL AND PE
PROTECT THE DEHUMIDIFIER AND THE LINE WITH A PROTECTION UPSTREAM
(REFERS TO THE PARAGRAPH “ELECTRICAL CONNECTIONS” FOR THE SUGGESTED PROTECTION)
BUS RS485 CONNECTION [OPTIONAL]: CONNECT TO THESE 2 CLAMPS THE BUS LINE COMING FROM THE DOMOTIC
OR SUPERVISION SYSTEM.
REFERS TO THE SERIAL MANUAL RS485
HYGROSTAT CONNECTION: CONNECT TO THESE 2 CLAMPS THE DRY CONTACT OF THE HYGROSTAT.
IF THE HYGROSTAT NEED TO BE SUPPLIED 230 V, CONNECT IT IN PARALLEL TO THE DEHUMIDIFIER ELECTRICAL
SUPPLY (F and N CLAMPS)