EasyManua.ls Logo

Higen FDA6000C Series - Page 73

Higen FDA6000C Series
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5. Parameter Setting
5-24
Menu Menu title Description Unit Range Default
*P7-06 MPG Pulse[REV] User 0~100000 100
Set command pulse or MPG pulse input quantity.
Ex) If set to P7-05=1, P7-06=100, when MPG pulse is putted 100 pulse motor rotates one
revolution
Namely, pulse number/one revolution= P7-06/P7-05= 100 pulse / 1 rotation
Menu Menu title Description Unit Range Default
*P7-07 Angle Division
Angle division stop
when Jog operation
User 0~1000 0
When using turret operation mode, as in the case of stopping in JOG operation, Set the ordinary
rate of the angle that is stopped.
Ex) If set value=30
When operating in JOG Mode, as in the case of inputting the stop command in optional
angle only stop the multiples of 30 degree which is set
(Danger !) RUN_MODE[P8-01]: Only applied in zero turret operation Digital Loader
As in the case of IJOG transportation by Digital Loader and stop by input contact
point STOP. Angle-division-stop doesn’t operate

Table of Contents

Related product manuals