Appendix Parameter table
-4
P09-04
Monitor Offset 1 mV -1000.0 ~ 1000.0 0.0 Speed/Torque/Position
P09-05
Monitor 2 - 0 ~ 5 1 Speed/Torque/Position
P09-06
Monitor ABS 2 - ON/OFF OFF Speed/Torque/Position
P09-07
Monitor Scale 2 - 0.1 ~ 2000.0 1.0 Speed/Torque/Position
P09-08
Monitor Offset 2 mV -1000.0 ~ 1000.0 0.0 Speed/Torque/Position
JOG-01
Key Jog Mode - ON/OFF OFF Speed/Torque/Position
JOG-02
Key Jog Speed rpm -9999.9 ~ 9999.9 100.0 Speed/Torque/Position
JOG-03
Auto Jog Mode - 0 ~ 2 0 Speed/Torque/Position
JOG-04
Jog Speed 1 rpm -9999.9 ~ 9999.9 100.0 Speed/Torque/Position
JOG-05
Jog Time1/REV1 [sec]/[rev] 0.00 ~ 5000.00 1.00 Speed/Torque/Position
JOG-06
Jog Speed 2 rpm -9999.9 ~ 9999.9 -100.0 Speed/Torque/Position
JOG-07
Jog Time2/REV2 [sec]/[rev] 0.00 ~ 5000.00 1.00 Speed/Torque/Position
JOG-08
Jog Speed 3 rpm -9999.9 ~ 9999.9 200.0 Speed/Torque/Position
JOG-09
Jog Time3/REV3 [sec]/[rev] 0.00 ~ 5000.00 1.00 Speed/Torque/Position
JOG-10
Jog Speed 4 rpm -9999.9 ~ 9999.9 -200.0 Speed/Torque/Position
JOG-11
Jog Time4/REV4 [sec]/[rev] 0.00 ~ 5000.00 1.00 Speed/Torque/Position
JOG-12
Jog Speed 5 rpm -9999.9 ~ 9999.9 400.0 Speed/Torque/Position
JOG-13
Jog Time5/REV5 [sec]/[rev] 0.00 ~ 5000.00 1.00 Speed/Torque/Position
JOG-14
Jog Speed 6 rpm -9999.9 ~ 9999.9 -400.0 Speed/Torque/Position
JOG-15
Jog Time6/REV6 [sec]/[rev] 0.00 ~ 5000.00 1.00 Speed/Torque/Position
JOG-16
Jog Speed 7 rpm -9999.9 ~ 9999.9 800.0 Speed/Torque/Position
JOG-17
Jog Time7/REV7 [sec]/[rev] 0.00 ~ 5000.00 1.00 Speed/Torque/Position
JOG-18
Jog Speed 8 rpm -9999.9 ~ 9999.9 -800.0 Speed/Torque/Position
JOG-19
Jog Time8/REV8 [sec]/[rev] 0.00 ~ 5000.00 1.00 Speed/Torque/Position
ALS-01
Current Alarm - - nor Speed/Torque/Position
ALS-02
Alarm Reset - ON/OFF OFF Speed/Torque/Position
ALS-03
Alarm History 1 - 0 ~ 32 0 Speed/Torque/Position
ALS-04
Alarm History 2 - 0 ~ 32 0 Speed/Torque/Position
ALS-05
Alarm History 3 - 0 ~ 32 0 Speed/Torque/Position
ALS-06
Alarm History 4 - 0 ~ 32 0 Speed/Torque/Position
ALS-07
Alarm History 5 - 0 ~ 32 0 Speed/Torque/Position
ALS-08
Alarm History 6 - 0 ~ 32 0 Speed/Torque/Position
ALS-09
Alarm History 7 - 0 ~ 32 0 Speed/Torque/Position
ALS-10
Alarm History 8 - 0 ~ 32 0 Speed/Torque/Position
ALS-11
Alarm History 9 - 0 ~ 32 0 Speed/Torque/Position
ALS-12
Alarm History 10 - 0 ~ 32 0 Speed/Torque/Position
ALS-13
History Reset - ON/OFF OFF Speed/Torque/Position
The parameter with the () symbol cannot be changed when the SVONEN input contact point is “ON”.