3. Parameter setting
3-13
Speed
0
Torque
P02-22
P02-23
Gain
Gain1
Gain2
Command speed
Actual speed
Internal
command speed
-P02-23
-P02-22
P02-24
Contact Gain TC
Unit
ms
Display range
0.0 ~ 10000.0
Manufactured
default
100.0
Speed/Torque/
Position control
When executing the control gain conversion by the external input contact point, it decides the
control gain conversion time.
P02-24 = 100 [ms]
Gain conversion
contact point
(GAITRS)
OFF ON OFF
Gain1
Gain2
Gain1
Applied gain
P02-25
Temporary Stop
Unit
-
Display range
ON / OFF
Manufactured
default
OFF
Speed/Torque/
Position control
As the stop function, it sets the operation type of the set input contact point. Depending on the
menu value, the stop operation is converted.