EasyManua.ls Logo

HikRobot ID3000 Series - Set 2 D Code Quality Evaluation

HikRobot ID3000 Series
101 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ID3000 Series Smart Code Reader User Manual
40
Accurate Timeout Enable
If it is enabled, the accuracy of algorithm timeout will improve.
8.2.5 Set 2D Code Quality Evaluation
After 2D Code Quality Enable, you can set specific parameters according to actual demands.
Note
The function of code quality evaluation may differ by device models.
In test mode, this function is enabled by default. In normal mode, you need to enable it
manually.
Steps
1. Set Sym Proc Type according to actual demands, and the default type is Type 1. Type 1 has a
strong capacity to locate codes.
2. Set Iso Edition, including Iso15415 and Iso29158
Iso15415 is applicable to the quality evaluation for label 2-dimensional codes.
Iso29158 is applicable to the quality evaluation for DPM format 2-dimensional codes.
3. Set Verify Edition, including standard mode and HIK mode.
Standard mode is a standard quality evaluation mode.
HIK mode is a professional quality evaluation mode.
4. Set Standard Aperture and Magnification.
Standard aperture refers to a standard aperture, and its default value is 400.
Magnification is 150 by default.
Note
Standard Aperture and Magnification should be configured only when Type 2 is selected as Sym
Proc Type.
5. Click to start acquisition, and the client software will display the overall code quality in the
history area.
Figure 8-17 2D Code Quality Evaluation
Note
The overall grade includes A, B, C, D and F. A means that the code quality is the best while F means

Table of Contents