ID3000 Series Smart Code Reader User Manual
44
Figure 8-21 Set and Execute Hardware Trigger Mode
Set and Execute Counter Trigger Mode
Counter specifies that the trigger source will be generated after the set number of valid signals
appears. For example, if you set the Count Number to 3, the trigger source will be generated after
3 signals appear.
Steps
1. Click I/O Control Settings Input Trigger Mode.
2. Select On as Trigger Mode.
3. Select Counter 0 as Trigger Source.
4. Set Trigger Delay, Count Number, Count Source and Line Out Trigger In Polarity according to
actual demands.
Figure 8-22 Set and Execute Counter Trigger Mode
Set and Execute TCP Trigger Mode
TCP start specifies the TCP server as the source for the trigger signal. When the server receives the
specified string text, the trigger signal will be outputted.
Click I/O Control Settings Input Trigger Mode, select On as Trigger Mode and select TCP