2. Check the checkbox to enable report uploading.
3. Enter the report-uploading period (unit: hour). The report-uploading period
represents the time interval between uploading the first report and the next
report.
4. Enter the first report uploading time interval (unit: minute). The first report
uploading time interval represents the time interval between enabling the
report uploading function and sending the first report.
5. Select a center type.
6. Enter the center name and phone number.
The maximum length of center name is 32 characters.
The phone number should be 31 characters and the input mode is
{No.}{Dwell Time}{EXT No.}. For example, in the number of
000088075998FFF8180, the letter F (which means 2 seconds)
represents the dwell time, if the number of the letter F is N, the dwell
time is N*F seconds. The number of F is suggested to be more than 3,
which means the dwell time should be more than 6 seconds.
7. Enter the dialing times (1~15). The dialing times represents the times that the
control panel trying to communicate the alarm receiving center.
8. Select the Pstn protocol.
9. Select the Pstn transmission mode: DTMF5/S and DTMF10/S.
10. Enter the receiver ID which is the authentication account while doing the
communication with the alarm receiving center.
11. Click Apply to save the settings.