Control Panel User Manual
61
Command
Command
Description
Command
Command
Description
0
OFF
1
T1
2
T2
3
N1
4
N2
5
G1
6
G2
{6} End the command.
There are 6 channels (T1, T2, N1, N2, G1 and G2) of the network security
control panel. Each channel can be only used once during the center group
uploading configuration, no matter it is served as the main channel or backup
channel,
Center Group Zone Alarm Report Configuration
To configure the center group zone alarm report, please refer to the following
command.
613 0 000 #
1
3
4
2
{1} Center Group Zone Alarm Report Programming Address: 613, 617,
621, 625, 629 and 633.
Command
Command
Description
Command
Command
Description
613
Center Group 1 Zone
Alarm Report
Programming Address
617
Center Group 2
Zone Alarm Report
Programming
Address
621
Center Group 3 Zone
Alarm Report
625
Center Group 4
Zone Alarm Report

Table of Contents