Check to add data on alarm triggered capture of thermal channel.
Picture Quality
Set picture quality as high, medium, or low.
Add Original Data on Stream
Add and save original raw data to stream. The funcon requires higher network bandwidth.
Data Refresh Interval
It means the refresh interval of original data.
Display Pixel-to-Pixel Thermometry Data on Stream
Add and save
real-me pixel-to-pixel thermometry data to stream. The funcon requires
higher network bandwidth.
The funcon varies according to dierent camera models.
Pixel-to-Pixel Thermometry Data Refresh Interval
It means the refresh interval of thermometry data added to the stream.
Unit
Display temperature with Degree Celsius (°C)/Degree Fahrenheit (°F)/Degree Kelvin (K).
Temperature Range
Select the temperature measurement range. The device can adjust the temperature range
automacally if you select Auto.
Atmospheric Temperature
Set the atmospheric temperature.
Atmospheric Humidity
Set the atmospheric humidity.
Atmospheric Transmissivity
Set the atmospheric transmissivity from 0 to 1.
Distance Mode
Select the distance mode for temperature measurement. Fixed Distance and
Self-Adapon
are selectable. Fixed distance mode is suitable for xed objects or objects move in a very
small area.
Self-adapon mode is suitable for moving objects. In this mode, device
automacally adjusts parameters according to the distance to objects, so as to ensure
temperature measurement accuracy.
Version
View the version of current algorithm.
Calibraon File Version
View the version of calibraon le.
Alarm Interval
Set the alarm interval between two alarms.