Figure 6-21 Alarm Input
Note
Local alarm input: Local alarm input is triggered by the external device that connected to the
video recorder's terminal block.
2. Click of a desired alarm input.
Figure 6-22 Edit Alarm Input
3.
Customize Alarm Name.
4. Set alarm type as N.O (normally open) or N.C (normally closed).
5. Set Sengs as Input to enable the funcon.
Note
If you set Sengs as Nonuse, the alarm input will be disabled. If you set Sengs as One-Key
Disarmig, the selected linkage method(s) of the alarm input will be disabled.
6. Set the arming schedule. Refer to Congure Arming Schedule for details.
7. Set the linkage
acons. Refer to Congure Alarm Linkage Acon for details.
8. Click Apply.
Alarm Output
Trigger an alarm output when an alarm is triggered.
Steps
1. Go to Conguraon → Event → Normal Event → Alarm Output .
Figure 6-23 Alarm Output
2. Click of a desired alarm output.
3. Customize Alarm Name.
4. Select Dwell Time.