Note
Time periods shall not be repeated or overlapped.
Figure 6-26 Set Arming Schedule
3. Click Apply.
6.4.5
Congure Alarm Linkage Acon
Congure Alarm Pop-up Window
When an alarm is triggered, the local monitor displays in full screen the video image from the
alarming channel congured for full screen monitoring. And when the alarm is triggered
simultaneously in several channels, you must
congure the auto-switch dwell me.
Steps
1. Go to
Conguraon → System → Live View → General .
2. Set the event output and dwell me.
Alarm Pop-up Output
Select the output to show event video.
Alarm Pop-up Delay
Set the me in seconds to show alarm event image. If alarms are triggered simultaneously in
several channels, their full-screen images will be switched at an interval of 10 seconds
(default dwell
me).
3. Click Linkage Acon of the alarm detecon.
4. Select Alarm Pop-up Window alarm linkage acon.
5. Select the channel(s) in Trigger Channel sengs you want to make full screen monitoring.
Note
Auto-switch will terminate once the alarm stops and back to the live view interface.
Network Video Recorder User Manual