3.2 Set Detecon Parameters
Set radar detecon parameters according to the actual needs and installaon environment.
Steps
1.
Click Falling Monitoring.
Figure 3-2 Set Detecon Parameters
2.
View the radar informaon.
Radar Status
The current radar status. The radar can be normally used in normal status. If the radar is in
upgrading status, do not reboot the device.
Soware Version
The soware version of the radar.
3.
Set the radar detecon parameters.
Event Triggered Time
If the target falls and stands up within the set Event Triggered Time, the system will not
output fall alarm.
Sensivity Threshold of Human Body Detecon
The higher the value is, the less sensive the detecon will be. The default value is
recommended.
4.
Set
Detecon Area.
5.
Oponal: You can also do the following operaons.
Adjust the view scale.
Export Data Click Export Data, select the saving path, and click OK to export the
locaon informaon.
Fall Detecon Radar User Manual
6